Filter Results By:

Products

Applications

Manufacturers

Showing results: 256 - 270 of 338 items found.

  • Digital Fault Recording

    SHERLOG - KoCoS Messtechnik AG

    Fault recorder systems with a power quality analyser for comprehensively monitoring and assessing low, medium and high voltage networks in power plants and transformer substations. The measuring devices of the SHERLOG range make very high-resolution recordings of all the disturbances which occur in power supply systems. The behaviour of protection and switchgear devices during these system disturbances is recorded at the same time.

  • Power Quality Analyzer

    PQM-702 - Sonel S.A.

    *Power to the analyzer is supplied from tested mains (internal power supply) and is used in all types of networks from 64 V to 760 V.*With particular emphasis on measurements at low voltage poles, due to the ease of connection.*Has an independent power supply socket, especially suited for voltage measurements for transformers and DC circuits.*Remote control and data transfer through a built-in GSM modem (GPRS).*Anti-theft feature - SMS notification in the event of position change - built-in GPS receiver.*Real-time clock synchronized to GPS protocol.

  • Military-Style DC Solid-State Relay for High-Current Pulse Load Applications

    Part No. M33-2N - Teledyne Defense Electronics Relays & Coax Switch

    The M33-2N is a military-style DC solid-state relay designed for high-current pulse load applications. It features the latest power FET output technology to minimize ON resistance. This feature provides minimum output voltage drop and allows the M33-2N to switch high pulse currents up to 100 amps at higher temperatures than those allowable with bipolar devices. The M33-2N utilizes transformer isolation to protect against transients, and are through-hole mountedMSL 1 Available options include:M33-2 7Adc, 60Vdc Load; 4.5-5.5Vdc (bias voltage), 80µA (CMOS) Control;

  • AC Resonant Test System

    Yangzhou Power Electric Co., Ltd

    Testing of certain apparatus requires much high voltage or current that a straight AC test system is not sufficient. Thus resonant test reactor with a variable core is needed. The main advantage of such test systems is lower input power and larger output power. The resonant test system is designed to compensate capacitance in the testing circuit precisely by tuning inductance of the test system. AC resonant test system is used for factory testing of middle, high and ultra-high voltage cables, capacitors, generators, motors, power transformers and gas-insulated switchgears.

  • Primary Injection Test Set

    PI-6000 - ETI Precision

    The PI-6000 is a rugged & durable primary injection test set capable of testing circuit breakers up to 6,000 amperes frame size. It incorporates an output transformer with dual primaries to facilitate its use on power sources of 480 VAC as well as 208-240 VAC. The unit also includes dual secondaries to provide optimal impedance matching to a wide range of circuit breaker sizes. An internal voltage sensor automatically configures the AC control power section to be energized only when properly configured for the applied voltage.

  • Adjustable Isolating Transformers

    PeakTech Prüf- und Messtechnik GmbH

    The PeakTech 2235 is a 2 in 1 laboratory isolating transformer with integrated DC power supply, which was designed with the aspect of high safety requirements for use in research, science and repair. The device has a dual adjustable DC, AC output, which can also be used for constant voltage or current and offers high stability and performance. The output voltage or the output current can be read exactly on two separate 3-digit LED displays and the fixed output supplies a voltage of 5 V. The device is protected against damage by overload and short circuit by reliable overvoltage protection and can be placed in a 19 ”rack installed or used as a table device (“stand-alone”).

  • AC Test Transformer

    Shanghai Guantu Technology Co., Ltd.

    How the AC test transformer prevents the overvoltage generated by the frequency conversion series resonance test device is a relatively simple problem, but the overvoltage caused by voltage fluctuation is difficult to appear when the overvoltage protection is set. Generally, the overvoltage of the frequency conversion series resonance test device will appear in the frequency sweep stage of the instrument, that is, in the process of finding the resonance point. Those who have used it know that in the process of finding the resonance point of the frequency conversion series resonance test device, the voltage and frequency have a parabola-like linear relationship. By default, the system finds the high voltage, that is, the apex of the parabola as the resonance point.

  • LVDT Sensor Amplifiers

    Analog Devices Inc.

    Analog Devices signal conditioning ICs, together with linear variable differential transformers (LVDTs), can be used to convert mechanical position to a dc voltage. The IC provides both the excitation for the LVDT and the output conversion to dc level with a user selectable gain. ADI LVDT signal conditioners are available to interface with a wide range of LVDTs, including half bridge and standard 4- and 5-wire.

  • Resistive AC Load Bank

    Junxy Energy

    AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.

  • Embedded Synchro - Resolver -

    LVDT I/O Cards - Computer Conversions Corporation

    100% Transformer Isolation is offered for all AC I/O, and various Isolated DC converters are available as standard product, eliminating concerns for ground-loops, ground interjected (intermittent and ghostly) field noise, inductive surges, differing potentials, and high voltage field transients from effecting the card itself, the sensitive ISA bus backplane and any other device or system sharing these signals.

  • Automatic Three Phase Transformer Ratio Meter

    ATRM PLUS - Eltel Industries

    *Fully Automatic measurement.*Wide selection of Excitation Voltages of 10V, 40V, 100V, 230V & 250V from front panel.*4V Excitation voltage provided for CT measurements*Ratio range of up to 5000; direct display of measured ratio.*No conversions required.*Automatic Jumper selecting as per the vector*Diagram of Transformer.*Automatic testing of all 3 phases in 3 phase transformers*Without manual intervention.*Displays % deviation from a nominal ratio.*External storage facility using pen drive.*Internal storage up to 10000 readings.*Touch screen 7” Color TFT display with backlighting with*Resolution of 800 X 480.*Tap changer facility.*Computer interface using RS-232 or USB.*Windows Interface software provided for data transfer.*USB printer interface.*Four terminal measurements to reduce errors due to*Winding and lead resistance.*Auto print and storage facility.Fast measurements.

  • PXIe-4340, PXI Displacement Input Module

    785068-01 - NI

    The PXI Displacement Input Module supports 4-, 5-, and 6-wire AC linear variable differential transformer (LVDT) and AC rotary variable differential transformer (RVDT) measurements. The module simultaneously samples each analog input and sets the excitation frequency and voltage for each channel independently. You can set different timing, triggering, and sampling modes for each channel independently. Diagnostic features include self-calibration, overcurrent detection, and open coil detection.The PXI Displacement Input Module includes the NI-DAQmx driver and configuration utility that simplify configuration and measurements. NI-DAQmx supports NI programming environments as well as Python, ANSI C, C#.NET, and MathWorks MATLAB® software.

  • HIGH VOLTAGE SCR CONTROLLED POWER SUPPLY

    xPS Series - Carl E. Holmes Company

    High Voltage SCR Controlled Power Supply, P/N 18278PS Power Rating: 350 KW. Input: 480 VAC, 3 PH, 60 Hz Output: 0 to 5000 VDC, 70 Amps max Ripple: 2 % approximately at maximum rated voltage Configuration: 12 pulse externally SCR controlled rectifier system Protection Devices: Input contactors Overload relay shutoff Input surge suppressor Thermal switches Output current limiting resistor (made with 5 Ohm Kanthal heating element) Emergency power shutoff Cooling: Each 6 pulse rectifier assembly is cooled by three 10” fans Interface: 4/20 ma converter interface for output voltage and output current to SCR controller. Enclosure: The overall dimension of the unit is (78”H x 38”W x 53”D). It is comprised of two separate enclosures each with dimensions of (78” H x 38” W x 26” D) which are integrated together to form a single enclosure. Each half enclosure has one 6 pulse transformer and one 6 pulse high voltage rectifier. Weight: Approx. 5000 lbs. SCR Controller: The 12 pulse SCR controller is supplied by the customer. We were responsible for the 12 pulses Transformer and 12 pulses Rectifier section. Portability: Unit can be lifted up with a fork lift. It can also be moved around with a 5000 lb pallet jack. Transformer: Two 200 KVA transformers are used to step 480 VAC to 3750 VAC each in a 12 pulse configuration Rectifiers: Two 6 pulse rectifier assemblies capable for 5000 VDC and 60 Amps output were used. The high voltage rectifier assemblies are isolated and protected in a fiberglass plenum within the enclosure. Blocking Diode: Each diode of the 6 pulse rectifier consists of 10 diodes in series to offer a blocking voltage of 12000 V (PIV)

  • Analog Power Supply

    Type NPS-2412 - National RF, Inc

    National RF's Type NPS-2412 analog power supply was designed to be used in communication equipment where radiated switching inverter noise from conventional “switching type” supplies is not acceptable. The power supply consists of a standard rectified transformer output driving a pair of voltage regulators and filtering networks. The 2412 offers an adjustable voltage output between 2 and 24 volts as well as a fixed voltage output of 12 volts. A maximum of 20 Watts of DC power can be supplied from the unit. As the voltage regulators dissipate power in the regulation process, the power to the load is derated accordingly, dependent on the set voltage to the load. The adjustable regulator is a standard LM-317T integrated circuit device. The fixed regulator is a standard LM 7812 device. Upon customer request, the LM 7812 device may be changed to any voltage rating within the the LM-78xx series of regulators. Contact National RF for this modification if desired.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

Get Help